ULTRA - ECA approved High Intensity Radiant Plaque Heaters

  On/Off 7On/Off 14On/Off 21On/Off 28On/Off 42Hi/Lo 7/3.5Hi/Lo 14/7Hi/Lo 21/10.5Hi/Lo 28/14Hi/Lo 42//21
Technical Specification
Input - kW 6.6613.3319.9826.6639.966.66/ 3.3313.33/ 6.6619.98/ 9.9926.27/ 13.3339.96/ 19..98
Length -mm 78011501520189026607801150152018902660
Width -mm 580
Height -mm 350
Weight - KG 14223039541422303954
Gas Connection Rc - 1/2
Supply Pressure Natural Gas - Min 17mbar Max 25mbar; Propane - Min 25mbar Max 45mbar
Electrical Supply 230v ~ 50Hz 25W Current Rating 0.055A
Mouting Height
Horizontal 3m-9m4m-12m5m-15m6m-18m8m-24m3m-9m4m-12m5m-15m6m-18m8m-24m
Angle > 30 Degrees 2.5m-6m3m-9m3.5m-12m4.5m-12m7m-12m2.5m-6m3m-9m3.5m-12m4.5m-12m7m-21m
Minimum Clearances To Combustibles
Front - Horizontal 670mm1000mm1365mm1510mm2260mm670mm1000mm1365mm1510mm2260mm
Back - Horizontal 670mm1000mm1365mm1510mm2260mm670mm1000mm1365mm1510mm2260mm
Front - 45 Degrees 950mm2000mm2480mm2590mm3890mm950mm2000mm2480mm2590mm3890mm
Back - 45 Degrees 225mm335mm365mm405mm500mm225mm335mm365mm405mm500mm
Above 1000mm
Below 1340mm2840mm3080mm3680mm5520mm1340mm2840mm3080mm3680mm3890mm
Side 670mm1255mm1365mm1670mm2510mm670mm1255mm1365mm1670mm2510mm
ULTRA -  ECA approved High Intensity Radiant Plaque

Industrial Tube Heaters
Industrial Plaque Heaters
Poultry Brooders
Poultry Tube Heaters