EPA-SS-IP55 Agricultural Radiant Tube Heater

The SPACE-RAY EPA-SS-IP55 (EPA-IP55) is a protected agricultural radiant tube heater that creates a heating effect similar to the sun inside poultry houses. It warms the chicks and the ground around them rather than the air, giving birds warm access to food and water.

Radiant energy travels from the heater and only turns into heat when it meets the chicks or the litter at floor level, putting the warmth exactly where the birds need it.

How does an IP55 radiant tube heater work? A gas fired flame burns inside the Calorised Emitter Tube, which then gives off invisible “black heat” energy. Instead of warming the air, this energy heats the birds and the litter directly, making it an efficient and cost saving way to heat a poultry house.

The fully enclosed IP55 stainless steel burner box and fan keep out water and dust, which matters in a dusty poultry house and helps the heater give long, reliable service. Its push through system includes TISS™, the Tube Integrity Safety System, which shuts down the gas controls if the heater overheats or the tube is damaged. You can choose a single or two stage burner, and the heater can be flued to remove combustion gases, including CO2, from the building.

A range of heat outputs and emitter lengths, supplied in lightweight 3m sections, lets you match the system to the size of your building.

TISS

Need to ask a question? Call Us: + 44 (0) 1473 830 551

Features

  • Four model ratings
  • Three emitter package lengths available
  • IP55 rated burner box and fan, complete with fresh air flexible connector, clips, suspension hooks and outlet screen
  • 5 Year emitter tube guarantee
  • Calorised Emitter Tube - Highly efficient
  • Calorised Emitter Tube - flake-free - guaranteed
  • Lightweight construction - supplied in 3m sections - easy to assemble and fit
  • Aluminium radiant reflectors - the tested proven superior material - designed to maximise downward radiation
  • All units individually tested before despatch
  • Made in the UK under ISO 9001 quality assurance
  • CE marked for both Natural Gas and LPG
  EPA-SS L 12 EPA-SS L 15 EPA-SS L 20 EPA-SS L 25 EPA-SS L 30 EPA-SS L 38 EPA-SS L 45 EPA-SS L 55
Technical Specification
Input – kW 11.5 15.0 20.0 25.0 30.0 37.0 45.0 53.0
Input – kW – 2 Stage 8.10 10.5 14.0 17.5 21.0 25.9 31.5 37.1
Length – m 4.93 – 6.46 6.46 – 12.55 9.5 – 12.55 12.55 – 18.65 15.6 – 21.7
Width -mm 330
Height -mm 370
Gas Connection All Models R -1/2
Supply Pressure Natural Gas – G20 20mbar Propane – G31 37mbar
Electrical Supply 230v~50Hz 90w, Current rating 0.39A, Fuse externally 3A
Flue Diameter 100mm Dia.
Air Inlet Connection 101.6mm Dia.
Mouting Height
Horizontal 2.4m – 6.0m 3.0m – 8.0m 3.8m – 10.0m 4.0m – 12.5m 5.6m-15m 6.0m-15m
Angle > 30 Degrees 2.1m – 4.5m 2.7m – 5.0m 3.3m – 7.0m 3.7m – 8.0m 4.8m-11m 5.2m-11m
Minimum Clearances To Combustibles
Side mm 560 710 860 1060
Above mm 150
Below mm 1320 1420 1520 1780 1930 2060 2180
End mm 380 510
Front mm 1020 1220 1320 1470 1680 1780 1910
Rear mm 300