ADL ADU Advantage Radiant Tube Heaters

The SPACE-RAY ADL ADU radiant tube heater belongs to the Advantage range and comes in two layouts, the U tube ADU and the linear ADL. With five sizes of each, from 23kW to 47kW heat input, the range gives you ten models to match the size and height of your building.

Like every SPACE-RAY Advantage heater, the ADL ADU uses double aluminium reflectors with an air gap between them, which helps retain heat and direct radiant energy downwards. The range is ErP 2025 compliant, with seasonal efficiency of up to 82.4% and BREEAM efficiency figures of up to 92.6%. Every unit is also CE and UKCA approved.

From warehouses, distribution centres and factories to sports centres, garages, showrooms, retail stores and restaurants, Advantage heaters suit a wide mix of commercial and industrial buildings. They work well in large, tall areas and in spaces with a high air change rate.

How does a radiant tube heater work? Inside the Calorised Emitter Tube, a gas fired flame heats the tube until it radiates invisible “black heat” energy. Much like sunshine, this energy warms the people, objects and surfaces it reaches rather than the air, so it suits both whole building heating and zone or spot heating.

Need to ask a question? Call Us: + 44 (0) 1473 830 551

Features

  • 5 Year emitter tube guarantee
  • Calorised Emitter Tube - Highly efficient
  • Calorised Emitter Tube - flake-free - guaranteed
  • Lightweight construction - 4" tubes supplied in 3m sections - easy to assemble and fit
  • Double Aluminium radiant reflectors - the proven superior material to maximise downward heat
  • All units individually tested before despatch
  • Made in the UK under ISO 9001:2008 quality assured
  • CE marked for both Natural Gas and LPG

ADU

  ADU25 ADU30 ADU35 ADU40 ADU45
Technical Specification
Input – kW 23.0 29.20 34.50 42.20 47.0
Length -mm 5385mm 5510mm 6970mm
Width -mm 460mm 715mm
Height -mm 175mm 210mm
Weight – KG 47kg 66kg 81kg
Gas Connection All Models R -1/2
Supply Pressure Natural Gas – Min 17mbar, Max 25mbar; Propane – Min 25mbar, Max 45mbar; Butane – Min 20mbar, Max 35mbar
Electrical Supply 230v~50Hz 125w, Current rating at 0.55A, Fuse externally 3A
Flue Diameter All models – 100mm
Air Inlet Connection All Models – 101.6mm
Mounting Height
Horizontal 3.0m – 8.0m 3.8m – 10.0m 4.0m – 12.5m 4.8m – 13.5m 5.6m – 15m
Angle > 30 Degrees 2.7m – 5.0m 3.3m – 7.0m 3.7m – 8.0m 4.0m – 9.0m 4.8m – 11m
Minimum Clearances To Combustible Materials – mm
Side 510 760
Above 450 610
Below 1220 2285
End 510 610
Front 610 760
Rear 305 380

 

ADL

  ADL25 ADL30 ADL35 ADL40 ADL45
Technical Specification
Input – kW 23.0 29.20 34.50 42.20 47.0
Length -mm 10065mm 9955mm 13000mm
Width -mm 340mm
Height -mm 180mm
Weight – KG 46kg 62kg 79kg
Gas Connection All Models R -1/2
Supply Pressure Natural Gas – Min 17mbar, Max 25mbar; Propane – Min 25mbar, Max 45mbar; Butane – Min 20mbar, Max 35mbar
Electrical Supply 230v~50Hz 125w, Current rating at 0.55A, Fuse externally 3A
Flue Diameter 100mm
Air Inlet Connection 101.6mm
Mounting Height
Horizontal 3.0m – 8.0m 3.8m – 10.0m 4.0m – 12.5m 4.8m – 13.5m 5.6m-15m
Angle > 30 Degrees 2.7m – 5.0m 3.3m – 7.0m 3.7m – 8.0m 4.0m – 9.0m 4.8m-11m
Minimum Clearances To Combustible Materials – mm
Side 510 760
Above 450 610
Below 1220 2285
End 510 610
Front 610 760
Rear 305 380