EPA-U U Tube Radiant Heater

The SPACE-RAY EPA-U is a U tube radiant heater from the EPA push burner range. As a U shaped radiant tube heater, it bends the tube back on itself, so standard models are just 3.79m to 8.88m long. Extended versions reach up to 11.88m and create an even larger radiant heat pattern.

The fan and burner share a single enclosure and drive the heater as a push through, positive pressure system. With the fan motor fully enclosed in the burner box, the EPA-U runs at less than 50dB(A).

If the tube overheats or is damaged, TISS™, the Tube Integrity Safety System, steps in. Its low voltage circuit watches the clearance above the reflector, then breaks the safety circuit to shut down the gas controls.

Choose from eight models with heat inputs from 11.5kW to 53kW, in single and two stage versions, all built from lightweight tube sections no longer than 3m. The EPA range reaches up to 82.1% seasonal efficiency, with BREEAM figures of up to 91.2%.

Where can you use a U tube radiant heater? In buildings from factories, industrial units and warehouses to garages, retail stores and sports centres. The Calorised Emitter Tube radiates invisible “black heat” energy that warms people and surfaces rather than the air, so you can heat a whole building or target a single zone.

Need to ask a question? Call Us: + 44 (0) 1473 830 551

Features

  • Part L 2010 & EcoDesign Compliant
  • Eight model ratings: 12kW to 55kW available in Linear and 'U' models
  • Single Stage and Two Stage Modulating Inputs available
  • Push Through System (Positive Pressure)
  • Tube Integrity Safety System (TISS™)
  • Blower motor totally enclosed in the burner box.
  • 5 Year emitter tube guarantee
  • Calorised Emitter Tube - Highly efficient
  • Calorised Emitter Tube - flake-free - guaranteed
  • Lightweight construction - 4" tubes supplied in 3m sections - easy to assemble and fit
  • Aluminium radiant reflectors - the proven superior material to maximise downward heat
  • All units individually tested before despatch
  • Made in the UK under ISO 9001:2008 quality assured system
  • CE marked for both Natural Gas and LPG
EPA U 12 EPA U 15 EPA U 20 EPA U 25 EPA U 30 EPA U 38 EPA U 45 EPA U 55
Technical Specification
Input – kW 11.5 15 20 25 30 37 45 53
Input – kW – 2 Stage 8.1 10.5 14 17.5 21 25.9 31.5 37.1
Length – m 3.79 3.79 – 6.84 5.31 – 6.84 5.31 – 9.88 6.84 – 9.88 8.36 – 11.41
Width -mm 790
Height -mm 370
Gas Connection All Models R -1/2
Supply Pressure Natural Gas – G20 20bar Propane – G31 37mbar
Electrical Supply 230v~50hz 90w, Current rating 0.39A, Fuse externally 3A
Flue Diameter 100mm Dia.
Air Inlet Connection 101.6mm Dia.
Mounting Height
Horizontal 2.4m – 6.0m 3.0m – 8.0m 3.8m – 10.0m 4.0m – 12.5m 5.6m-15m 6.0m-15m
Angle > 30 Degrees 2.1m – 4.5m 2.7m – 5.0m 3.3m – 7.0m 3.7m – 8.0m 4.8m-11m 5.2m-11m
Minimum Clearances To Combustibles
Side mm 560 710 860 1060
Above mm 150
Below mm 1320 1420 1520 1780 1930 2060 2180
End mm 380 510
Front mm 1020 1220 1320 1470 1680 1780 1910
Rear mm 300